HeartStart OnSite/HS1 AED – philips
0 out of 5
₹0.00
Availability: 10 in stock
SKU: HeartStart-AED-PHILIPS
- Description
- Size Guide
- Reviews (0)
- Store Policies
- Inquiries
Description
HeartStart OnSite/HS1 AED
The Philips HeartStart OnSite/HS1 is the first and only defibrillator available without a prescription. Designed for the ordinary person in the extraordinary moment, HeartStart Onsite/HS1 is easy to set-up and includes automatic Life Guidance features like voice prompts and CPR coaching to help guide you step-by-step through the treatment of sudden cardiac arrest.
Specifications Show less
- Battery
-
Type 9 volt DC, 4.2 Ah, composed of disposable long-life lithium manganese dioxide primary cellsCapacity Minimum 200 shocks or 4 hours of operating time (EN60601-2-4:2003)Install-by Date Battery is labeled with an install-by date of at least five years from date of manufactureStandby Life Four years typical when battery is installed by the install-by date. (Will power the AED in standby state within the specified Standby Temperature range, assuming one battery insertion test and no defibrillation uses) - Product Specifications
-
Kit Contents Defibrillator, battery (one, pre-installed), SMART Pads (one set, pre-installed), set-up/maintenance guide with expiration date tags, owner’s manual, quick reference guideWaveform SMART Truncated exponential biphasic. Waveform parameters adjusted as a function of patient impedanceDefibrillation peak current – Adult 32 A (150 J nominal) into a 50 ohm loadDefibrillation peak current – Pediatric 19 A (50 J nominal) into a 50 ohm load (using optional infant/child SMART Pads Cartridge)Shock-to-Shock Cycle Time Typically less than 20 seconds between shocks in a seriesQuick Shock Able to deliver a shock after the end of a CPR interval, typically in eight secondsVoice Instructions Detailed voice messages guide responder through use of the defibrillatorCPR Coaching Instructions for adult and infant/child CPR available at user selectionShock Delivery Via adhesive pads placed on patient’s bare skin as illustrated on padsControls Green SMART Pads cartridge handle, green On/Off button, blue i-button, orange Shock buttonIndicators Ready light, blue i-button, caution light - Environmental/Physical Requirements
-
Sealing Solid objects per EN60529 class IP2X; Drip-proof per EN60529 class IPX1Operating Temperature 0 – 50 °C (32 – 122 °F)Standby Temperature 0 – 43 °C (32 – 109 °F)Operating Humidity 0 to 95 % relative humidity (non-condensing)Standby Humidity 0 to 75 % relative humidity (non-condensing)Operating Altitude 0 to 4,500 m (0 to 15,000 ft)Standby Altitude <gt/> 48 hours from 0 to 8,500 ft and <lt/>48 hours from 8,500 to 15,000 ftShock/Drop Abuse Tolerance Withstands 1 meter drop to any edge, corner, or surfaceVibration Meets EN1789 random and swept sine, road ambulance specification in operating and standby statesEMI (Radiated/Immunity) Meets EN55011 Group 1 Level B Class B and EN61000-4-3 - SMART Pads
-
Energy delivered Adult: nominal 150 joules into a 50 ohm load; Infant/Child: nominal 50 joules into a 50 ohm loadHow Supplied Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solutionActive Surface Area 85 cm² (13.2 in²) eachCable Length Adult pads: 137 cm (54″); Infant/Child pads: 102 cm (40″)Use-by Date Cartridge is labeled with a use-by date of at least two years from date of manufactureTraining pads (optional) Special pads put HeartStart OnSite into training mode and disable its energy delivery capability. Training pads feature 8 real-world training scripts. Use with training mat (included) or with adapters on manikins - Automated and User-activated Self-tests
-
Daily Automatic Self-tests Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacityPads Integrity Test Specifically tests readiness-for-use of pads (gel moisture)Battery Insertion Test Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readinessStatus Indicator Blinking green “Ready” light indicates ready for use. Audible “chirp” indicates need for maintenance - Data Recording and Transmission
-
Infrared Wireless transmission of event data to a PC or Palm PDA, using the IrDA protocolData Stored First 15 minutes of ECG and the entire incident’s events and analysis decisions

size | chest(in.) | waist(in.) | hips(in.) |
---|---|---|---|
XS | 34-36 | 27-29 | 34.5-36.5 |
S | 36-38 | 29-31 | 36.5-38.5 |
M | 38-40 | 31-33 | 38.5-40.5 |
L | 40-42 | 33-36 | 40.5-43.5 |
XL | 42-45 | 36-40 | 43.5-47.5 |
XXL | 45-48 | 40-44 | 47.5-51.5 |