Clover Hba1c Analyzer
CLOVER HbA1c Analyzer is a fully automated boronate affinity assay for the determination of the percentage of hemoglobin A1c ( HbA1c %) in human whole blood. Automated boronate affinity assay measures a persons average blood sugar levels over 3 months period, haemoglobin A1c screens, helps, diagnose, monitors pre-diabetes and diabetes levels.
hba1c analyzer identifies the quantity of glycated haemoglobin (created when glucose bind to haemoglobin) in the blood. HbA1c Analyzer Clover made in korea with low cost per test very reliable cartridge system tamper proof test buy from Microsidd trusted medical supplier
Clover hbA1c Analyzer
only needs a small blood sample (4 µl) and has a short testing time (only 5 minutes). It is able to analyze in both capillary whole blood and venous blood This makes it the ideal point-of-care testing device. This HbA1c point of care testing device is an easy-to-use professional analyser which can be used in hospitals, GP offices, pharmacies and laboratories.
- Small blood sample: only 4µl
- Fast: test results in just 5 minutes
- Innovative: boronate-affinity technology
- Displays results in %, or mmol/mol or both untis
- Memory capacity: 200 tests results
- Easy to use, no refrigeration
Blood glucose test:
The Clover HbA1c Analyzer can test the blood glucose level by simply connecting the Glucose Module.
Transfer test results to a computer:
Use the PC connection Cable (USB) to download and manage the test results via a computer.
Printing test results with the thermal printer:
When the Clover hbA1c Analyzer LCD display is showing the test result, simply press the printer button and the test result is printed by the thermal printer.
The Clover HbA1c Analyzer test cartridge includes a cartridge and a reagent pack containing the reagents necessary for the determination of haemoglobin A1c, with a collection leg for blood sample collection.
The reagent pack is pre-filled with a reaction solution and a washing solution. The reaction solution contains agents that lyse erythrocytes and bind Hemoglobin
specifically, as well as a boronate resin that binds cis-diols of glycated Hemoglobin.
A blood sample of 4µl is obtained at the collection leg of the reagent pack. The reagent pack is inserted into the cartridge where the blood is instantly lysed releasing
the Hemoglobin and the boronate resin binding the glycated Hemoglobin.
The cartridge is inserted into the Clover A1c Analyzer. The blood sample mixture is rotated to the measurement zone of the cartridge, where the amount of total
haemoglobin is the blood sample is measured by the reflectance of the photo sensor LED (Light Emitting Diode) and PD (Photo Diode).
Then the assembled cartridge is rotated so that the washing solution washes out non-glycated Hemoglobin from the blood sample, thus the amount of glycated
Hemoglobin can be photometrically measured.
The ratio of glycated Hemoglobin with respect to total Hemoglobin in the blood sample is calculated.
PRINCIPLES OF OPERATION The CLOVER HbA1c
Self system is a fully automated boronate affinity assay for the determination of the percentage of Hemoglobin A1c (HbA1c %) in whole blood(capillary and venous). The Test Cartridge is composed of a cartridge and a reagent pack containing the reagents necessary for the determination of hemoglobin A1c. A cartridge should be inserted into the analyzer cartridge holder first and later assembled with a reagent pack which was applied with 4ul blood sample at the sample collecting area. A reagent pack is composed of reaction solution and washing solution. The reaction solution contains hemolyzing agent which lyses the red blood cells, and boronate resin which binds to the cis-diolsof glycated hemoglobin. The washing solution cleans the nonspecific glycated hemoglobin(except HbA1c) The blood sample(4uL) is collected at the collection area of the reagent pack, then the reagent pack is inserted into the cartridge, where the blood is instantly lysed releasing the hemoglobin and the boronate resin binding the glycated hemoglobin. The assembled cartridge is inserted into the CLOVER A1c™ Self Analyzer and rotated so that the sample mixture is placed at the measurement zone of the cartridge, where the amount of total hemoglobin in the blood sample is photometrically the diffused reflectance of the optical sensor composed with LED(Lgiht Emitting Diode) andPD(Photo Diode) Then, the assembled cartridge is rotated so that the washing solution washes out non-glycated hemoglobin from the blood sample, thus the amount of glycated hemoglobin can be photometrically measured. The ratio of glycated Hemoglobin with respect to total hemoglobin in the blood sample is calculated.
Compare Clover Hba1c Analyzer with other brands
erba hba1c analyzer |
roche hba1c analyzer |
biorad hba1c analyzer |
siemens hba1c analyzer |
sysmex hba1c analyzer |
abbott hba1c analyzer |
agappe hba1c analyzer |
Brand: Clover
Manufacturer: Infopia
Origin: South Korea
Type: Fully Automatic
Version: Table Top
Module: Point Of Care Testing
Machine Cost: Very Economic
Running Cost: Very Economic